---+ Quick 3hr Antibiotic Rescue Verification ---++ Overview This short protocol describes a simple same-day verification of antibiotic removal/"rescue" from counter-selection plates (e.g., AZT). Typically, rescue transformations are verified by PCR at the antibiotic cassette rescue loci, but sometimes this needs to be performed in >10 colonies due to low efficiency transformations or leaky counter selection media where scape mutants are frequent. Therefore, the following quick test can be performed prior to PCR confirmation, avoiding time-consuming PCR checks and limiting failed PCR verifications. ---+++ Materials * Colonies from counter-selection plate * Small 5mL tubes (Falcon Polystyrene Round-Bottom Tube) * Sterile (new box) P10/P20 tips ---+++ Procedure 1 Set 150uL media with the antibiotic to be tested in a new tube 1 <span style="background-color: transparent">Lightly touch a colony with a sterile tip and make sure some cells are visible on the tip. If colonies are large, avoid transferring a large clump of cells, all you need is a slightly (barely) visible amount.</span> 1 <span style="background-color: transparent">Drop tip with cells into tube. </span> 1 <span style="background-color: transparent">Set to incubate at 37C and 100-200 rpm.</span> 1 3-4 hrs later check if growth or no growth. ---+++ Tips * <span style="background-color: transparent">It's highly recommended you label each tested colony on the counter-selection plate (e.g., a, b, c, d...etc.). This will allow you to keep the plate, locate and re-use the assayed colonies.</span> * <span style="background-color: transparent">If the colonies are big enough, simultaneous incubation can be made as in steps 1-5 but without adding the antibiotic, so you have a liquid culture ready for downstream use or PCR verification.</span> * It doesn't matter whether the 5mL Falcon tube caps are tighly sealed or not. Barely any evaporation happens within 5 hr period and aerobic growth will still be possible even if sealed during this short time. After removing the tubes from the incubator, you can tighly seal their caps to prevent them from evaporation and keep the results visible for days to come. * If you transfer a large clump of cells to the test tube used, it could cause enough turbitity in the low 150uL media amount. This may confuse test results, leading to conclude wrongly there was growth. Just make sure to use a "barely" visible amount of cells, if not, you'll probably need to re-test if uncertain by re-inoculating from the test tube into another tube with antibiotic in it. -- Main.GabrielSuarez - 22 Mar 2018
Edit
|
Attach
|
Watch
|
P
rint version
|
H
istory
:
r4
<
r3
<
r2
<
r1
|
B
acklinks
|
V
iew topic
|
More topic actions...
Barrick Lab
>
ProtocolList
>
ProtocolsAntibioticRemovalVerification
Contributors to this topic
GabrielSuarez
Topic revision: r1 - 2018-03-22 - 20:26:42 - Main.GabrielSuarez
Barrick Lab
Contact
Research
Publications
Team
Protocols
Reference
Software
UT Austin
Mol Biosciences
ILS
Microbiology
EEB
CSSB
CBRS
The LTEE
iGEM team
SynBioCyc
SynBio course
NGS course
BEACON
Search
Log in
Copyright ©2025 Barrick Lab contributing authors. Ideas, requests, problems?
Send feedback